Brand Name : VEIKONG

Model Number : VFD500-PV

Certification : CE

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 15000pcs per Month

Delivery Time : depend on the order quantity

Packaging Details : the power less than 45kw use Carton, starting from 45kw use Wooden case

Product Name : 90kw solar water pump controller

Power : 90Kw/120hp

OEM : Accept

Warranty : 18 months

Voltage : 220v/380v

Application : Submersible pump

Contact Now

Solar water pump inverter 99% mppt 45kw 55kw 75kw 90kw pump controller

 

 
Main Features: ( Power range: 0.75kw-75kw 220v, 0.75kw-710kw 380v)
 

1, Built-in MPPT function and efficiency up to 99.6%

2, Could drive both AM and PMSM pump

3, Advanced software technology and perfect in driving PMSM pump

4, Perfect stability in output frequency

5, Remote control and monitoring by GPRS system(Available in PC and mobile)

6, Dry run function to protect the pump

7, Automatic start and stop function

8, DC and AC as input power source accepted

9, Standard LED keypad, optional LCD keypad

 

Software Desgin

1. Dual Supply Mode - Solar DC and Grid AC Compatible

2. Compatible with All Pumps, IM and PMSM
3. Dry Run Function
4. Automatic Start and Stop
5. Pumps Max Current Protection Setting
6. Water Tank Level Detect Function
 
 
Hardware Design

1. Innovation Design with Dual CPU

2. Good Ventilation with Low Temperature
3. Full Fault Protection Design to Ensure no IGBT Damaged
4. Infineon IGBT Module
5. Long Term Service Life Design
6. GPRS Remote Control is Option

 

 
Electrical Specifications and Power degree
 
  220V 380V
Max input DC voltage 450V 810V
DC voltage range 150~450VDC 300~810VDC
Normal working DC voltage 260V-400V 400V-650V
Recommended input mppt voltage 330V 550V
MPPT efficiency >99%
Rated output voltage 1/3-phase 220VAC 3-phase 380-480VAC
 

 
 
Accessories:
 
1. GPRS (support 2g/3g/4g internet)
 
90kw 120hp Solar Well Pump Controller
 
2. LCD keypad
 
 
90kw 120hp Solar Well Pump Controller
 
 
3. Output Reactor

90kw 120hp Solar Well Pump Controller
 
 
VFD500-PV solar pump inverter picture:
90kw 120hp Solar Well Pump Controller

90kw 120hp Solar Well Pump Controller

 

Mode Range

 

Drive model Max DC input current (A) Rated output current (A) Applicable water pump (kW)
VFD500M-40T00150-PV 9 3.7 1.5
VFD500M-40T00220-PV 12 5 2.2
VFD500M-40T00400-PV 16.5 9.4 4
VFD500M-40T00550-PV 23.9 13 5.5
VFD500M-40T00750-PV 30.6 17 7.5
VFD500-40T00150-PV 9 4.2 1.5
VFD500-40T00220-PV 12 5.6 2.2
VFD500-40T00400-PV 16.5 9.4 4
VFD500-40T00550-PV 23.9 13 5.5
VFD500-40T00750-PV 30.6 17 7.5
VFD50040T01100-PV 39.2 25 11
VFD500-40T01500-PV 49.0 32 15
VFD500-40T01850-PV 50 37 18.5
VFD500-40T02200-PV 60 45 22
VFD500-40T03000-PV 81 60 30
VFD500-40T03700-PV 90 75 37
VFD500-40T04500-PV 130 90 45
VFD500-40T05500-PV 150 112 55
VFD500-40T07500-PV 200 152 75
VFD500-40T09000-PV 250 176 90
VFD500-40T11000-PV 300 210 110
VFD500-40T13200-PV 360 253 132
VFD500-40T16000-PV 430 304 160
VFD500-40T18500-PV 500 360 185
VFD500-40T20000-PV 550 380 200
VFD500-40T22000-PV 620 426 220
VFD500-40T25000-PV 680 465 250
220V single phase/three phase level
VFD500-20T00075-PV 6.7 4.5 0.75
VFD500-20T00150-PV 9.9 7 1.5
VFD500-20T00220-PV 14.1 10.6 2.2
VFD500-20T00400-PV 22.6 17 4
VFD500-20T00550-PV 30 25 5.5

 

 

Connect wire diagram

 

90kw 120hp Solar Well Pump Controller

 

FAQ

 
1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
 
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
 
 
3.How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
 
4.If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

 

 

 


Product Tags:

120hp Solar Well Pump Controller

      

90kw Solar Well Pump Controller

      
Buy cheap 90kw 120hp Solar Well Pump Controller product

90kw 120hp Solar Well Pump Controller Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Veikong Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)